We evaluated the performance of the Vitek MS for identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories. With a total of 424 well-characterized isolates, the results of the Vitek MS were compared to those of conventional methods and 16S rRNA gene sequencing. The Vitek MS correctly identified 97.9 % of the isolates tested to species level. The Vitek MS correctly identified the species of 97.2 % of the staphylococci (95.9 % of coagulase-negative staphylococci), 97.8 % of the streptococci, and 100 % of the enterococci. For the identification of Gram-positive cocci isolates, the overall concordance rate between conventional identification and the Vitek MS was 94.5 %. The Vitek MS matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) system can be a reliable and rapid method for the identification of most relevant Gram-positive cocci. In addition, expanding the database of the Vitek MS, especially for coagulase-negative staphylococci, is needed to enhance the performance of the Vitek MS.

Loading

Article metrics loading...

/content/journal/jmm/10.1099/jmm.0.062950-0
2013-09-01
2019-10-16
Loading full text...

Full text loading...

/deliver/fulltext/jmm/62/9/1301.html?itemId=/content/journal/jmm/10.1099/jmm.0.062950-0&mimeType=html&fmt=ahah

References

  1. Benagli C. , Rossi V. , Dolina M. , Tonolla M. , Petrini O. . ( 2011; ). Matrix-assisted laser desorption ionization-time of flight mass spectrometry for the identification of clinically relevant bacteria. . PLoS ONE 6:, e16424. [CrossRef] [PubMed]
    [Google Scholar]
  2. Bizzini A. , Durussel C. , Bille J. , Greub G. , Prod’hom G. . ( 2010; ). Performance of matrix-assisted laser desorption ionization-time of flight mass spectrometry for identification of bacterial strains routinely isolated in a clinical microbiology laboratory. . J Clin Microbiol 48:, 1549–1554. [CrossRef] [PubMed]
    [Google Scholar]
  3. Cherkaoui A. , Hibbs J. , Emonet S. , Tangomo M. , Girard M. , Francois P. , Schrenzel J. . ( 2010; ). Comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry methods with conventional phenotypic identification for routine identification of bacteria to the species level. . J Clin Microbiol 48:, 1169–1175. [CrossRef] [PubMed]
    [Google Scholar]
  4. Christner M. , Rohde H. , Wolters M. , Sobottka I. , Wegscheider K. , Aepfelbacher M. . ( 2010; ). Rapid identification of bacteria from positive blood culture bottles by use of matrix-assisted laser desorption-ionization time of flight mass spectrometry fingerprinting. . J Clin Microbiol 48:, 1584–1591. [CrossRef] [PubMed]
    [Google Scholar]
  5. Chun J. , Lee J. H. , Jung Y. , Kim M. , Kim S. , Kim B. K. , Lim Y. W. . ( 2007; ). EzTaxon: a web-based tool for the identification of prokaryotes based on 16S ribosomal RNA gene sequences. . Int J Syst Evol Microbiol 57:, 2259–2261. [CrossRef] [PubMed]
    [Google Scholar]
  6. Claydon M. A. , Davey S. N. , Edwards-Jones V. , Gordon D. B. . ( 1996; ). The rapid identification of intact microorganisms using mass spectrometry. . Nat Biotechnol 14:, 1584–1586. [CrossRef] [PubMed]
    [Google Scholar]
  7. CLSI ( 2008; ). Interpretative Criteria for Identification of Bacteria and Fungi by DNA Target Sequencing; Approved Guideline MM18-A. . Wayne, PA:: Clinical and Laboratory Standards Institute;.
  8. Dubois D. , Grare M. , Prere M. F. , Segonds C. , Marty N. , Oswald E. . ( 2012; ). Performances of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for rapid identification of bacteria in routine clinical microbiology. . J Clin Microbiol 50:, 2568–2576. [CrossRef] [PubMed]
    [Google Scholar]
  9. Dubois D. , Segonds C. , Prere M. F. , Marty N. , Oswald E. . ( 2013; ). Identification of clinical Streptococcus pneumoniae isolates among other alpha and nonhemolytic streptococci by use of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system. . J Clin Microbiol 51:, 1861–1867. [CrossRef] [PubMed]
    [Google Scholar]
  10. Dupont C. , Sivadon-Tardy V. , Bille E. , Dauphin B. , Beretti J. L. , Alvarez A. S. , Degand N. , Ferroni A. , Rottman M. . & other authors ( 2010; ). Identification of clinical coagulase-negative staphylococci, isolated in microbiology laboratories, by matrix-assisted laser desorption/ionization-time of flight mass spectrometry and two automated systems. . Clin Microbiol Infect 16:, 998–1004.[PubMed] [CrossRef]
    [Google Scholar]
  11. Emonet S. , Shah H. N. , Cherkaoui A. , Schrenzel J. . ( 2010; ). Application and use of various mass spectrometry methods in clinical microbiology. . Clin Microbiol Infect 16:, 1604–1613. [CrossRef] [PubMed]
    [Google Scholar]
  12. Fang H. , Ohlsson A. K. , Ullberg M. , Ozenci V. . ( 2012; ). Evaluation of species-specific PCR, Bruker MS, VITEK MS and the VITEK 2 system for the identification of clinical Enterococcus isolates. . Eur J Clin Microbiol Infect Dis 31:, 3073–3077. [CrossRef] [PubMed]
    [Google Scholar]
  13. Fenselau C. , Demirev P. A. . ( 2001; ). Characterization of intact microorganisms by MALDI mass spectrometry. . Mass Spectrom Rev 20:, 157–171. [CrossRef] [PubMed]
    [Google Scholar]
  14. Harris P. , Winney I. , Ashhurst-Smith C. , O’Brien M. , Graves S. . ( 2012; ). Comparison of Vitek MS (MALDI-TOF) to standard routine identification methods: an advance but no panacea. . Pathology 44:, 583–585. [CrossRef] [PubMed]
    [Google Scholar]
  15. Kaleta E. J. , Clark A. E. , Cherkaoui A. , Wysocki V. H. , Ingram E. L. , Schrenzel J. , Wolk D. M. . ( 2011; ). Comparative analysis of PCR-electrospray ionization/mass spectrometry (MS) and MALDI-TOF/MS for the identification of bacteria and yeast from positive blood culture bottles. . Clin Chem 57:, 1057–1067. [CrossRef] [PubMed]
    [Google Scholar]
  16. Karas M. , Hillenkamp F. . ( 1988; ). Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. . Anal Chem 60:, 2299–2301. [CrossRef] [PubMed]
    [Google Scholar]
  17. Loïez C. , Wallet F. , Pischedda P. , Renaux E. , Senneville E. , Mehdi N. , Courcol R. J. . ( 2007; ). First case of osteomyelitis caused by “Staphylococcus pettenkoferi”. . J Clin Microbiol 45:, 1069–1071. [CrossRef] [PubMed]
    [Google Scholar]
  18. Marko D. C. , Saffert R. T. , Cunningham S. A. , Hyman J. , Walsh J. , Arbefeville S. , Howard W. , Pruessner J. , Safwat N. . & other authors ( 2012; ). Evaluation of the Bruker Biotyper and Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry systems for identification of nonfermenting gram-negative bacilli isolated from cultures from cystic fibrosis patients. . J Clin Microbiol 50:, 2034–2039. [CrossRef] [PubMed]
    [Google Scholar]
  19. Martiny D. , Busson L. , Wybo I. , El Haj R. A. , Dediste A. , Vandenberg O. . ( 2012; ). Comparison of the Microflex LT and Vitek MS systems for routine identification of bacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry. . J Clin Microbiol 50:, 1313–1325. [CrossRef] [PubMed]
    [Google Scholar]
  20. Neville S. A. , Lecordier A. , Ziochos H. , Chater M. J. , Gosbell I. B. , Maley M. W. , van Hal S. J. . ( 2011; ). Utility of matrix-assisted laser desorption ionization-time of flight mass spectrometry following introduction for routine laboratory bacterial identification. . J Clin Microbiol 49:, 2980–2984. [CrossRef] [PubMed]
    [Google Scholar]
  21. Schuurman T. , de Boer R. F. , Kooistra-Smid A. M. , van Zwet A. A. . ( 2004; ). Prospective study of use of PCR amplification and sequencing of 16S ribosomal DNA from cerebrospinal fluid for diagnosis of bacterial meningitis in a clinical setting. . J Clin Microbiol 42:, 734–740. [CrossRef] [PubMed]
    [Google Scholar]
  22. Seng P. , Drancourt M. , Gouriet F. , La Scola B. , Fournier P. E. , Rolain J. M. , Raoult D. . ( 2009; ). Ongoing revolution in bacteriology: routine identification of bacteria by matrix-assisted laser desorption ionization time-of-flight mass spectrometry. . Clin Infect Dis 49:, 543–551. [CrossRef] [PubMed]
    [Google Scholar]
  23. Song S. H. , Park J. S. , Kwon H. R. , Kim S. H. , Kim H. B. , Chang H. E. , Park K. U. , Song J. , Kim E. C. . ( 2009; ). Human bloodstream infection caused by Staphylococcus pettenkoferi. . J Med Microbiol 58:, 270–272. [CrossRef] [PubMed]
    [Google Scholar]
  24. Trülzsch K. , Rinder H. , Trcek J. , Bader L. , Wilhelm U. , Heesemann J. . ( 2002; ). “Staphylococcus pettenkoferi,” a novel staphylococcal species isolated from clinical specimens. . Diagn Microbiol Infect Dis 43:, 175–182. [CrossRef] [PubMed]
    [Google Scholar]
  25. van Veen S. Q. , Claas E. C. , Kuijper E. J. . ( 2010; ). High-throughput identification of bacteria and yeast by matrix-assisted laser desorption ionization-time of flight mass spectrometry in conventional medical microbiology laboratories. . J Clin Microbiol 48:, 900–907. [CrossRef] [PubMed]
    [Google Scholar]
  26. Yan Y. , He Y. , Maier T. , Quinn C. , Shi G. , Li H. , Stratton C. W. , Kostrzewa M. , Tang Y. W. . ( 2011; ). Improved identification of yeast species directly from positive blood culture media by combining Sepsityper specimen processing and Microflex analysis with the matrix-assisted laser desorption ionization Biotyper system. . J Clin Microbiol 49:, 2528–2532. [CrossRef] [PubMed]
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journal/jmm/10.1099/jmm.0.062950-0
Loading
/content/journal/jmm/10.1099/jmm.0.062950-0
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error