Tetrahymena elliotti was used to assess the accuracy of the volume distribution measured with a Coulter counter. The volumes of the cells were shown to be underestimated because of their electrical conductivity. Theoretical considerations predicted the observed excessive skewness of the distributions. It is concluded that the only reliable parameter obtained from a Coulter volume distribution is the mean size.
BehrensW.,
Von,
EdmondsonS.1976; Comparison of techniques improving the resolutior of standard Coulter sizing systems. Journa of Histochemistry and Cytochemistry 24:247–256
Ben-SassonS.,
PatinkinD.,
GroverN. B.,
DouanskiF.1974; Electrical sizing of particle in suspension. IV. Lymphocytes. Journal of Cellular Physiology 84:205–214
CurdsC. R.,
RobertsD..,
Mcl,
WuC.H.
1978; The use of continuous cultures and electronic sizing devices to study the growth of twc species of ciliated protozoa. In Techniques for the Study of Mixed Populations pp. 165–177LovelockD. W.,
DaviesR.
Edited by London: Academic Press;
FrickeH.1924; A mathematical treatment of the electric conductivity and capacity of disperse systems. I. The electrical conductivity of a suspension of homogeneous spheroids. Physical Review 24:575–587
GroverN. B.,
NaamanJ.,
Ben-SassonS.,
DouanskiF.1969b; Electrical sizing of particles in suspensions. II. Experiments with rigid spheres. Biophysical Journal 9:1415–1425
GroverN. B.,
NaamanJ.,
Ben-SassonS.,
DouanskiF.1972; Electrical sizing of particles in suspensions. III. Rigid spheroids and red blood cells. Biophysical Journal 12:1099–1117
HellemanP. W.1972The Coulter Electronic Particle Counter. Aspects and Views in Counting and Sizing of Erythrocytes Nijkerk, The Netherlands: Koninklijke Drukkerij C. C. Callenbach N. V.;
KachelV.1976; Basic principles of electrical sizing of cells and particles and their realization in the new instrument “Metricell”. Journal of Histochemistry and Cytochemistry 24:211–230
KitchingJ. A.1967; Contractile vacuoles, ionic regulation and excretion. In Research in Protozoology1 pp. 309–336ChenT. T.
Edited by Oxford: Pergamon Press;
MundschenkD. D.,
ConnellyD. P.,
WhiteJ. G.,
BrunningR. D.1976; An improved technique for the electronic measurement of platelet size and shape. Journal of Laboratory and Clinical Medicine 88:301–315
NanneyD. L.,
MccoyJ. W.1976; Characterization of the species of the Tetrahymena pyriformis complex. Transactions of the American Microscopical Society 95:664–681
RickettsT. R.,
RappittA. F.1974; Determination of the volume and surface area of Tetrahymena pyriformis and their relationship to endocytosis. Journal of Protozoology 21:549–551
RifkinJ. L.1968; Coupling of a measuring eyepiece to a voltage divider to allow the continuous display of measured microscopic dimensions. Analytical Biochemistry 24:192–196
SchmidP.1967; Temperature adaptation of the growth and division process of Tetrahymena pyriformis. I. Adaptation phase. Experimental Cell Research 45:460–470
ThomR.,
HampeA.,
SauerbreyG.1969; Die elektronische Volumenbestimmung von Blutkdr- perchen und ihre Fehlerquellen. Zeitschrift für die gesamte experimented Medizin 151:331–349