A fatal case of nosocomial legionellosis in a low prevalence region (Calgary, Alberta, Canada) prompted investigation into the source of infection. Hospital water systems contaminated with Legionella pneumophila have been shown to pose a risk to compromised patients. Typing of an L. pneumophila serogroup 1 strain isolated from the patient using sequence-based typing (SBT) and amplified fragment length polymorphism (AFLP) analysis linked it to a persistent and widespread strain isolated from the hospital water system establishing a nosocomial mode of acquisition. Different SBT and AFLP patterns were determined for non-epidemiologically linked cases and isolates from different hospitals.
Amemura-MaekawaJ.,
KuraF.,
ChangB.,
WatanabeH.2005; Legionella pneumophila serogroup 1 isolates from cooling towers in Japan form a distinct genetic cluster. Microbiol Immunol 49:1027–1033[CrossRef]
BlattS. P.,
ParkinsonM. D.,
PaceE.,
HoffmanP.,
DolanD.,
LauderdaleP.,
ZajacR. A.,
MelcherG. P.1993; Nosocomial Legionnaires' disease: aspiration as a primary mode of disease acquisition. Am J Med 95:16–22[CrossRef]
FryN. K.,
Exiou-DanielS.,
BangsborgJ. M. & 11 other authors; 1999; A multicenter evaluation of genotypic methods for the epidemiologic typing of Legionella pneumophila serogroup 1: results of a pan-European study. Clin Microbiol Infect 5:462–477[CrossRef]
FryN. K.,
BangsborgJ. M.,
BernanderS. & 11 other authors; 2000; Assessment of intercentre reproducibility and epidemiological concordance of Legionella pneumophila serogroup 1 genotyping by amplified fragment length polymorphism analysis. Eur J Clin Microbiol Infect Dis 19:773–780[CrossRef]
GreenbergA. E.,
ClesceriL. S.,
EatonA. D.
(editors) 1998; Legionella. In Standard Methods for the Examination of Water and Wastewater pp. 9-106–9-109 Washington: American Public Health Association, American Water Works Association, Water Environment Federation;
PerolaO.,
KauppinenJ.,
KusnetsovJ.,
KarkkainenU. M.,
LuckP. C.,
KatilaM. L.2005; Persistent Legionella pneumophila colonization of a hospital water supply: efficacy of control methods and a molecular epidemiological analysis. APMIS 113:45–53[CrossRef]
ScaturroM.,
LosardoM.,
De PonteG.,
RicciM. L.2005; Comparison of three molecular methods used for subtyping of Legionella pneumophila strains isolated during an epidemic of legionellosis in Rome. J Clin Microbiol 43:5348–5350[CrossRef]
ValsangiacomoC.,
BaggiF.,
GaiaV.,
BalmelliT.,
PeduzziR.,
PiffarettiJ. C.1995; Use of amplified fragment length polymorphism in molecular typing of Legionella pneumophila and application to epidemiological studies. J Clin Microbiol 33:1716–1719