1887

Abstract

Summary

In a prospective study, the Gen-Probe PACE 2 (GP) assay was compared with Abbott Laboratories’ ligase chain reaction (LCR) assay for the detection of . A total of 493 female patients consented to collection of two cervical samples; a first-void urine (FVU) sample was collected also from 446 of the participants. Cervical samples were tested by both GP and LCR; 16 samples (3.1%) tested positive by both methods and no discrepant results were observed. All but one of the FVU samples collected from patients with a positive cervical sample was positive for by LCR. The stability of FVU samples over time in the LCR test was also evaluated and proved to be significantly longer than the 4 days stated by the manufacturer. While LCR proved to be highly sensitive in detecting chlamydial infection in FVU samples, no difference was noted between LCR and GP in the detection of cervical infection in this study population.

Loading

Article metrics loading...

/content/journal/jmm/10.1099/00222615-48-5-507
1999-05-01
2024-04-25
Loading full text...

Full text loading...

http://instance.metastore.ingenta.com/content/journal/jmm/10.1099/00222615-48-5-507
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error