A multiplex polymerase chain reaction (PCR), involving detection of the mecA and femB genes, was combined with a novel immunoassay system capable of detecting specific PCR products. The resulting PCR-immunoassay was evaluated in comparison with conventional microbiological techniques used in the routine diagnostic laboratory for the rapid identification of methicillin-resistant Staphylococcus aureus (MRSA), either in pure culture or in overnight broth cultures obtained following enrichment of patient screening swabs. Among the 480 purified isolates of staphylococci and 246 enrichment broths examined, only one ‘false-negative’ result was obtained by PCR, compared with 18 ‘false-negative’ results obtained by conventional methodology and demonstrated by further conventional examination. Five demonstrable ‘false-positive’ results were obtained by conventional methodology, compared with a possible 10 by the PCR-immunoassay, although it was not certain that these 10 PCR results were true ‘false positives’ as, by definition, MRSA could not be isolated by conventional methodology. The results indicated that the routine diagnostic laboratory was encountering difficulties in identifying MRSA correctly, and that the conventional microbiological techniques lacked sensitivity. Overall, the PCR technique was more accurate and sensitive than conventional methodology in detecting MRSA, and results were available within 24 h of screening swabs arriving in the laboratory, compared with a minimum of 48–72 h by conventional techniques. The immunoassay system added to the usefulness of the method by allowing the detection of specific PCR products within 5 min of completing the PCR, without the normal additional step of agarose gel electrophoresis.
CoxR. A.,
ConquestC.,
MallaghanC.,
MarplesR. R. A major outbreak of methicillin-resistant Staphylococcus aureus caused by a new phage-type (EMRSA-16). J Hosp Infect1995; 29:87–106
BignardiG. E.,
WoodfordN.,
ChapmanA.,
JohnsonA. P.,
SpellerD. C. E. Detection of the mec-A gene and phenotypic detection of resistance in Staphylococcus aureus isolates with borderline or low-level methicillin resistance. J Antimicrob Chemother1996; 37:53–63
CurranR.,
TalbotD. C. S.,
TownerK. J. A rapid immunoassay method for the direct detection of PCR products: application to detection of TEM /7-lactamase genes. J Med Microbiol1996; 45:76–78
BarrowG. I.,
FelthamR. K. A.
(eds) Cowan and Steel’s Manual for the identification of medical bacteria 3rd edn Cambridge: Cambridge University Press; 1993
KobayashiN.,
WuH.,
KojimaK. Detection of mecA, femA, and femB genes in clinical strains of staphylococci using polymerase chain reaction. Epidemiol Infect1994; 113:259–266
GehaD. J.,
UhlJ. R.,
GustaferroC. A.,
PersingD. H. Multiplex PCR for identification of methicillin-resistant staphylococci in the clinical laboratory. J Clin Microbiol1994; 32:1768–1772
VannuffelP.,
GigiJ.,
EzzedineH. Specific detection of methicillin-resistant Staphylococcus aureus species by multiplex PCR. J Clin Microbiol1995; 33:2864–2867
CoelloR.,
JiminezJ.,
GarciaM. Prospective study of infection, colonization and carriage of methicillin-resistant Staphylococcus aureus in an outbreak affecting 990 patients. Eur J Clin Microbiol Infect Dis1994; 13:74–81
HumphreysH.,
DuckworthG. Methicillin-resistant Staphylococcus aureus (MRSA) - a re-appraisal of control measures in the light of changing circumstances. J Hosp Infect1997; 36:167–170
UbukataK.,
NakagamiS.,
NittaA. Rapid detection of the mecA gene in methicillin-resistant staphylococci by enzymatic detection of polymerase chain reaction products. J Clin Microbiol1992; 30:1728–1733
KolbertC. P.,
ConnollyJ. E.,
LeeM. J.,