Evaluation of a recombinant antigen ELISA for the diagnosis of acute toxoplasmosis and comparison with traditional antigen ELISAs Free

Abstract

SUMMARY

An evaluation of five ELISA methods for the diagnosis of acute toxoplasmosis was undertaken by comparing a laboratory-produced ELISA employing two recombinant polypeptides as antigen with a laboratory-produced ELISA and three commercially available ELISAs employing traditional parasite antigen preparations derived from whole tachyzoites. With a panel of 75 sera from patients who showed either serological and clinical evidence of acute toxoplasmosis, or of diseases caused by other infectious agents, or from patients who showed no evidence of infectious disease, the ELISAs gave overall positive predictive values of 81.6–100%, negative predictive values of 87.8–100%, sensitivities of 81.3–100%, and specificities of 83.7–100%. No two ELISAs gave identical results with all sera tested. In total, the ELISA based on the two recombinant polypeptides appeared to be the most specific ELISA in this comparison, showing positive predictive values and specificities of 100% for all groups of patients tested. The overall negative predictive value for this ELISA was 87.8% and the sensitivity was 81.3%. Therefore, the ELISA based on recombinant antigen appears to be a promising advance in the serological diagnosis of acute toxoplasmosis.

Loading

Article metrics loading...

/content/journal/jmm/10.1099/00222615-37-6-404
1992-12-01
2024-03-29
Loading full text...

Full text loading...

/deliver/fulltext/jmm/37/6/medmicro-37-6-404.html?itemId=/content/journal/jmm/10.1099/00222615-37-6-404&mimeType=html&fmt=ahah

References

  1. Dubey J. P., Beattie C. P. Toxoplasmosis of animals and man. Boca Raton, FL, CRC Press 198841–48
    [Google Scholar]
  2. Johnson A. M. Toxoplasmosis serology. The Royal College of Pathologists of Australasia Quality Assurance Programme Microbiology Survey 1990; M5:7–8
    [Google Scholar]
  3. Johnson A. M. Toxoplasmosis serology. The Royal College of Pathologists of Australasia Quality Assurance Program Microbiology Survey 1989; M6:1–2
    [Google Scholar]
  4. Joynson D. H. M., Payne R. A., Balfour A. H., Prestage E. S., Fleck D. G., Chessum B. S. Five commercial enzyme-linked immunosorbent assay kits for Toxoplasma specific IgM antibody. J Clin Pathol 1989; 42:653–657
    [Google Scholar]
  5. Schaefer L. E., Dyke J. W., Meglio F. D., Murray P. R., Crafts W., Niles A. C. Evaluation of microparticle enzyme immuno-assays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer. J Clin Microbiol 1989; 27:2410–2413
    [Google Scholar]
  6. Herbrink P., Van Loon A. M., Rotmans J. P., Van Knapen F., Van Dijk W. C. Interlaboratory evaluation of indirect enzyme-linked immunosorbent assay, antibody capture enzyme-linked immunosorbent assay, and immunoblotting for detection of immunoglobulin M antibodies to Toxoplasma gondii . J Clin Microbiol 1987; 25:100–105
    [Google Scholar]
  7. Van Enk R. A., James K. K., Thompson K. D. Evaluation of three commercial enzyme immunoassays for Toxoplasma and cytomegalovirus antibodies. Am J Clin Pathol 1991; 95:428–434
    [Google Scholar]
  8. Johnson A. M., Illana S. Cloning of Toxoplasma gondii gene fragments encoding diagnostic antigens. Gene 1991; 99:127–132
    [Google Scholar]
  9. Parker S. J., Smith F. M., Johnson A. M. Murine immune responses to recombinant Toxoplasma gondii antigens. J Parasitol 1991; 77:402–409
    [Google Scholar]
  10. Tenter A. M., Vietmeyer C., Johnson A. M. Development of ELISAs based on recombinant antigens for the detection of Toxoplasma gondii – specific antibodies in sheep and cats. Vet Parasitol 1992 (in press)
    [Google Scholar]
  11. Tenter A. M., Johnson A. M. Recognition of recombinant Toxoplasma gondii antigens by human sera in an ELISA. Parasitol Res 1991; 77:197–203
    [Google Scholar]
  12. Naot Y., Barnett E. V., Remington J. S. Method for avoiding false-positive results occurring in immunoglobulin M enzyme-linked immunosorbent assays due to presence of both rheumatoid factor and antinuclear antibodies. J Clin Microbiol 1981; 14:73–78
    [Google Scholar]
  13. Johnson A. M., Roberts H., McDonald P. J., Rothe J. Detection of Toxoplasma-specific IgM in cord blood sera by antibody-class capture enzyme-linked immunosorbent assay. Pathology 1985; 17:586–589
    [Google Scholar]
  14. Johnson A. M., Gu Q. M., Roberts H. Antibody patterns in the serological diagnosis of acute lymphadenopathic toxo plasmosis. Aust NZ J Med 1987; 17:430–434
    [Google Scholar]
  15. Griner P. F., Mayewski R. J., Mushlin A. I., Greenland P. Selection and interpretation of diagnostic tests and procedures. Ann Intern Med 1981; 94:553–600
    [Google Scholar]
  16. Payne R. A., Joynson D. H. M., Balfour A. H. Public Health Laboratory Service enzyme-linked immunosorbent assay for detecting Toxoplasma specific IgM antibody. J Clin Pathol 1987; 40:276–281
    [Google Scholar]
  17. Campbell A. M. General properties and applications of monoclonal antibodies. In Burdon R. H., Van Knippenberg P. H. (eds) Laboratory techniques in biochemistry and mol ecular biology vol 13 Monoclonal antibody technology Amsterdam, Elsevier Science Publishers; 19841–32
    [Google Scholar]
  18. Mitchell G. F. Hybridomas in immunoparasitology. In Hurrell J. G. R. (ed) Monoclonal hybridoma antibodies : techniques and applications Boca Raton, CRC Press; 1982139–149
    [Google Scholar]
  19. Srivastava I. K., Takacs B., Caspers P. Recombinant polypeptides for serology of malaria. Trans R Soc Trop MedHyg 1989; 83:317–321
    [Google Scholar]
  20. Hedman K., Lappalainen M., Seppala I., Makela O. Recent primary Toxoplasma infection indicated by a low avidity of specific IgG. J Infect Dis 1989; 159:736–740
    [Google Scholar]
  21. Joynson D. H. M., Payne R. A., Rawal B. K. Potential role of IgG avidity for diagnosing toxoplasmosis. J Clin Pathol 1990; 43:1032–1033
    [Google Scholar]
  22. Siegel J. P., Remington J. S. Comparison of methods for quantitating antigen-specific immunoglobulin M antibody with a reverse enzyme-linked immunosorbent assay. J Clin Microbiol 1983; 18:63–70
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journal/jmm/10.1099/00222615-37-6-404
Loading
/content/journal/jmm/10.1099/00222615-37-6-404
Loading

Data & Media loading...

Most cited Most Cited RSS feed