Adherence of seven strains of Staphylococcus epidermidis and three strains of S. aureus to three types of intravascular catheters was assessed by ATP bioluminescence, by culture after ultrasonication and by scanning electronmicroscopy. The catheter materials studied were silicone elastomer, thermoplastic polyurethane and polyurethane and polyurethane coated with Hydromer®, a coating which absorbs water and provides a hydrophilic sheath around the catheter. The adherence assays were performed in phosphate-buffered saline on a rotary shaker at 37°C, with the catheters precoated with serum and uncoated, and the results were correlated with bacterial hydrophobicity. There was wide strain-to-strain variation in bacterial adherence; S. aureus and slime-producing S. epidermidis strains adhered better than did non-slime-producing strains. Overall, there was less bacterial adherence to Hydromer®-coated catheters than to polyurethane and silicone catheters but it was unrelated to bacterial hydrophobicity. Serum coating of catheters resulted in marked reduction of bacterial adherence.
ChristensenG. D.,
SimpsonW. A.,
BisnoA. L.,
BeacheyE. H.1982; Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces. Infection and Immunity 37:318–326
ChristensenG. D.1985; Adherence of coagulase-negative staphylococci to plastic tissue culture plates: a quantitative model for the adherence of staphylococci to medical devices. Journal of Clinical Microbiology 22:996–1006
HarberM. J.,
MacKenzieR.,
AsscherA. W.1983; A rapid bioluminescence method for quantifying bacterial adhesion to polystyrene. Journal of General Microbiology 129:621–632
HarveyM. P.,
TrentR. J.,
JoshuaD. E.,
Ramsey-StewartG.,
StoreyD. W.,
KronenbergH.1986; Complications associated with indwelling venous Hickman catheters in patients with hematological disorders. Australian and New Zealand Journal of Medicine 16:211–215
HogtA. H.,
DankertJ.,
FeijenJ.1985; Adhesion of coagulase-negative staphylococci with different surface characteristics onto a hydrophobic biomaterial. Antonie van Leeuwenhoek 51:510–512
HogtA. H.,
DankertJ.,
HulstaertC. E.,
FeijenJ.1986; Cell surface characteristics of coagulase-negative staphylococci and their adherence to fluorinated poly(ethylenepropylene). Infection and Immunity 51:294–301
KristinssonK. G.,
JonesG. I.,
OxleyK. M.,
HastingsJ. G. M.1987; Rapid assay of staphylococcal adhesion to plastic microtitration trays. Journal of Medical Microbiology 24:vi (abstract)
LjunghA.,
HjertenS.,
WadstromT.1985; High surface hydropho bicity of autoaggregating Staphylococcus aureus strains isolated from human infections studied with the salt aggregation test. Infection and Immunity 47:522–526
LudwickaA.,
SwitalskiL. M.,
LundinA.,
PulvererG.,
WadstromT.1985; Bioluminescent assay for measurement of bacterial attachment to polyethylene. Journal of Microbiological Methods 4:169–177
MacKenzieA. M. R.,
Rivera-CalderonR. L.1985; Agar overlay method to measure adherence of Staphylococcus epidermidis to four plastic surfaces. Applied and Environmental Microbi ology 50:1322–1324
PascualA.,
FleerA.,
WesterdaalN. A. C.,
VerhoefJ.1986; Modulation of adherence of coagulase-negative staphylo cocci to teflon catheters in vitro. European Journal of Clinical Microbiology 5:518–522
PetersG.,
LocciR.,
PulvererG.1982; Adherence and growth of coagulase-negative staphylococci on surfaces of intravenous catheters. Journal of Infectious Diseases 146:479–482
SattlerF. R.,
FoderaroJ. B.,
AberR. C.1984; Staphylococcus epidermidis bacteremia associated with vascular catheters: an important cause of febrile morbidity in hospitalised patients. Infection Control 5:279–283
SeifertL. M.,
GreerR. T.1985; Evaluation of in-vivo adsorption of blood elements on to hydrogel-coated silicone rubber by scanning electron microscopy and fourier transform in frared spectroscopy. Journal of Biomedical Materials Research 19:1043–1071
SheretzR. J.,
FalkR. J.,
HuffmanK. A.,
ThomannC. A.,
MattemW. D.1983; Infections associated with subclavian Uldall catheters. Archives of Internal Medicine 143:52–56
ShethN. K.,
RoseH. D.,
FransonT. R.,
BuckmireF. L. A.,
SohnleP. G.1983; In-vitro quantitative adherence of bacteria to intravascular catheters. Journal of Surgical Research 34:213–218