1887

Abstract

It has now been established that transmissible spongiform encephalopathy (TSE) infectivity, which is highly resistant to conventional methods of deactivation, can be transmitted iatrogenically by contaminated stainless steel. It is important that new methods are evaluated for effective removal of protein residues from surgical instruments. Here, radio-frequency (RF) gas-plasma treatment was investigated as a method of removing both the protein debris and TSE infectivity. Stainless-steel spheres contaminated with the 263K strain of scrapie and a variety of used surgical instruments, which had been cleaned by a hospital sterile-services department, were examined both before and after treatment by RF gas plasma, using scanning electron microscopy and energy-dispersive X-ray spectroscopic analysis. Transmission of scrapie from the contaminated spheres was examined in hamsters by the peripheral route of infection. RF gas-plasma treatment effectively removed residual organic residues on reprocessed surgical instruments and gross contamination both from orthopaedic blades and from the experimentally contaminated spheres. testing showed that RF gas-plasma treatment of scrapie-infected spheres eliminated transmission of infectivity. The infectivity of the TSE agent adsorbed on metal spheres could be removed effectively by gas-plasma cleaning with argon/oxygen mixtures. This treatment can effectively remove ‘stubborn’ residual contamination on surgical instruments.

Loading

Article metrics loading...

/content/journal/jgv/10.1099/vir.0.81016-0
2005-08-01
2024-03-28
Loading full text...

Full text loading...

/deliver/fulltext/jgv/86/8/vir862393.html?itemId=/content/journal/jgv/10.1099/vir.0.81016-0&mimeType=html&fmt=ahah

References

  1. Baxter H. C., Baxter R. L., Jones A. C., Whittaker A. G. 2005; Improved plasma cleaning method . 0501460.0 (UK patent applied for
  2. Belkin N. L. 2003; Medical device reprocessing. AORN J 77:543–544
    [Google Scholar]
  3. Brown P., Preece M., Brandel J.-P. 12 other authors 2000; Iatrogenic Creutzfeldt–Jakob disease at the millennium. Neurology 55:1075–1081 [CrossRef]
    [Google Scholar]
  4. DesCoteaux J. G., Poulin E. C., Julien M., Guidoin R. 1995; Residual organic debris on processed surgical instruments. AORN J 62:23–30 [CrossRef]
    [Google Scholar]
  5. Dinakaran S., Kayarkar V. V. 2002; Debris on processed ophthalmic instruments: a cause for concern. Eye 16:281–284 [CrossRef]
    [Google Scholar]
  6. Fichet G., Comoy E., Duval C. 7 other authors 2004; Novel methods for disinfection of prion-contaminated medical devices. Lancet 364:521–526 [CrossRef]
    [Google Scholar]
  7. Flechsig E., Hegyi I., Enari M., Schwarz P., Collinge J., Weissmann C. 2001; Transmission of scrapie by steel-surface-bound prions. Mol Med 7:679–684
    [Google Scholar]
  8. Jackson G. S., McKintosh E., Flechsig E. 7 other authors 2005; An enzyme–detergent method for effective prion decontamination of surgical steel. J Gen Virol 86:869–878 [CrossRef]
    [Google Scholar]
  9. Kibria S. M. G., Kerr K. G., Dave J., Gough M. J., Homer-Vanniasinkam S., Mavor A. I. D. 2002; Bacterial colonisation of Doppler probes on vascular surgical wards. Eur J Vasc Endovasc Surg 23:241–243 [CrossRef]
    [Google Scholar]
  10. Kimberlin R. H., Walker C. A. 1978; Evidence that the transmission of one source of scrapie agent to hamsters involves separation of agent strains from a mixture. J Gen Virol 39:487–496 [CrossRef]
    [Google Scholar]
  11. Marsh R. F., Kimberlin R. H. 1975; Comparison of scrapie and transmissible mink encephalopathy in hamsters. II. Clinical signs, pathology, and pathogenesis. J Infect Dis 131:104–110 [CrossRef]
    [Google Scholar]
  12. Mayor S. 2003; UK government advises tighter measures to reduce risk of CJD transmission during neurosurgery. BMJ 326:517
    [Google Scholar]
  13. McLeod A. H., Murdoch H., Dickinson J. 7 other authors 2004; Proteolytic inactivation of the bovine spongiform encephalopathy agent. Biochem Biophys Res Commun 317:1165–1170 [CrossRef]
    [Google Scholar]
  14. Miller D. M., Youkhana I., Karunaratne W. U., Pearce A. 2001; Presence of protein deposits on ‘cleaned’ re-usable anaesthetic equipment. Anaesthesia 56:1069–1072 [CrossRef]
    [Google Scholar]
  15. Nürnberg M., Schulz H. J., Rüden H., Vogt K. 2003; Do conventional cleaning and disinfection techniques avoid the risk of endoscopic Helicobacter pylori transmission?. Endoscopy 35:295–299 [CrossRef]
    [Google Scholar]
  16. Prusiner S. B. 1991; Molecular biology of prion diseases. Science 252:1515–1522 [CrossRef]
    [Google Scholar]
  17. Smith A., Dickson M., Aitken J., Bagg J. 2002; Contaminated dental instruments. J Hosp Infect 51:233–235 [CrossRef]
    [Google Scholar]
  18. Sugawara M., Stansfield B. L., Fujita H. 1998 Plasma Etching: Fundamentals and Applications Oxford: Oxford University Press;
    [Google Scholar]
  19. Tapp A. 2003; Reuse of single use medical devices. Can Oper Room Nurs J 21:18–19
    [Google Scholar]
  20. Whittaker A. G., Graham E. M., Baxter R. L., Jones A. C., Richardson P. R., Meek G., Campbell G. A., Aitken A., Baxter H. C. 2004; Plasma cleaning of dental instruments. J Hosp Infect 56:37–41 [CrossRef]
    [Google Scholar]
  21. Yan Z. X., Stitz L., Heeg P., Pfaff E., Roth K. 2004; Infectivity of prion protein bound to stainless steel wires: a model for testing decontamination procedures for transmissible spongiform encephalopathies. Infect Control Hosp Epidemiol 25:280–283 [CrossRef]
    [Google Scholar]
  22. Zerr I., Poser S. 2004; Epidemiology and risk factors of transmissible spongiform encephalopathies in man. Contrib Microbiol 11:98–116
    [Google Scholar]
  23. Zinn C. 2000; Nine hospital patients may have been exposed to CJD. BMJ 320:1296 [CrossRef]
    [Google Scholar]
  24. Zobeley E., Flechsig E., Cozzio A., Enari M., Weissmann C. 1999; Infectivity of scrapie prions bound to a stainless steel surface. Mol Med 5:240–243
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journal/jgv/10.1099/vir.0.81016-0
Loading
/content/journal/jgv/10.1099/vir.0.81016-0
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error